Daftar Parameter Teknis KYW3-4000
| Model pemutus sirkuit | syw3-4000 | ||||
| Nilai arus Masuk (40 ℃) (A) | 800、1000、1250、1600、2000、2500、3200、4000 | ||||
| Arus pengenal n-kutub | 100% Masuk | ||||
| Nilai tegangan kerja Ue (V) | AC220/230/240、AC380/400、AC415、AC440/480、AC660/690 | ||||
| Frekuensi terukur f (Hz) | 50/60 | ||||
| Tegangan isolasi terukur Ui (V) | 1250 | ||||
| Tegangan ketahanan impuls terukur Uimp (kV) | 12 | ||||
| Tiang nomor kutub | 3,4 | ||||
| Waktu istirahat penuh (ms) | ≤30 | ||||
| Waktu penutupan (md) | ≤70 | ||||
| Tipe putus | S | H | |||
| Nilai kapasitas pemutusan hubung singkat tertinggi Icu (nilai efektif) (kA) | AC220V/230V/240V, AC380V/400V | 85 | 100 | ||
| AC415V, AC440V/480V, AC660V/690V | 75 | 85 | |||
| Nilai kapasitas pemutusan arus pendek operasi Ics (nilai efektif) (kA) | AC220V/230V/240V, AC380V/400V | 85 | 100 | ||
| AC415V, AC440V/480V, AC660V/690V | 75 | 85 | |||
| Nilai kapasitas produksi jangka pendek Icm (nilai puncak) (kA) | AC220V/230V/240V, AC380V/400V | 187 | 220 | ||
| AC415V, AC440V/480V, AC660V/690V | 165 | 187 | |||
| Dinilai menahan arus dalam waktu singkat Icw (nilai efektif) 1s (kA) | AC220V/230V/240V, AC380V/400V | 85 | 100 | ||
| AC415V, AC440V/480V, AC660V/690V | 75 | 85 | |||
| Kinerja operasional | Umur listrik (kali) Frekuensi pengoperasian (20 kali/jam) | AC220V/230V/240V, AC380V/400V | 10000(800A~1600A)、8000(2000A、2500A)、6000(3200A、4000A) | ||
| AC415V, AC440V/480V, AC660V/690V | 10000(800A~1600A)、6000〔2000A、2500A}、3000(3200A、4000A) | ||||
| Umur mekanis (kali) Frekuensi pengoperasian (60 kali/jam) | Bebas perawatan | 10000 | |||
| Ada pemeliharaan | 15000 | ||||
| Metode instalasi | Tipe tetap, tipe Laci | ||||
| Metode pengkabelan sirkuit utama | Kabel horizontal, kabel vertikal, kabel ekstensi horizontal, kabel ekstensi vertikal | ||||
| Dimensi keseluruhan: L×D×T(mm) | Memperbaiki tipe 3P | 428 ×300×393,5 | |||
| Memperbaiki tipe 4P | 543×300×393,5 | ||||
| Tipe laci 3P | 435×403×432(800A~2500A) | 435×397.5×432(3200A、4000A) | |||
| Tipe laci 4P | 550×403×432(800A~2500A) | 550×397.5×432(3200A、4000A) | |||
| Berat (kg) | Memperbaiki tipe 3P | 59(800A~2500A) | 60 (3200A、4000A) | ||
| Memperbaiki tipe 4P | 70(800A~2500A) | 71,5(3200A,4000A) | |||
| Tipe laci 3P | 97(800A~2500A) | 103(3200A、4000A) | |||
| Tipe laci 4P | 114(800A~2500A) | 120(3200A、4000A) | |||